Different GE Multilin relays may be connected to the same twisted pair link providing they are all programmed with a unique address and the same baud rate. FIGURE 2– RS Connection / FEEDER PROTECTION RELAY – INSTRUCTION MANUAL 2– GE MULTILIN FEEDER PROTECTION RELAY NEW VAC, WITH COMMUNICATIONS. MANUFACTURER. General Electric. MANUFACTURER PART NUMBER. HI NOTES: Solid State or Microprocessor based relays are generally equipped with a large variable of settings and curve options and some Electromechanical relays provide for adjustable . The / has three standard outputs. The main trip output is used to activate the breaker trip coil in the event of a fault. The auxiliary trip output can follow the trip relay, act as an 86 Lockout, or trip only on ground faults while the main trip output trips only on phase faults. The relay service output is used to provide the relay status.


View and Download GE instruction manual online. FEEDER PROTECTION RELAY. relays pdf manual download. Also for: GE MULTILIN FEEDER PROTECTION RELAY NEW VAC, WITH COMMUNICATIONS. MANUFACTURER. General Electric. MANUFACTURER PART NUMBER. HI NOTES: Solid State or Microprocessor based relays are generally equipped with a large variable of settings and curve options and some Electromechanical relays provide for adjustable calibrated settings. Electrical Manuals for electrical equipment. / - FEEDER MANAGEMENT RELAY - Instruction Manual - Firmware Rev.: - Analog Rev.: 27HA - Control Rev.: 27HC


GE MULTILIN FEEDER PROTECTION RELAY NEW VAC, WITH COMMUNICATIONS. MANUFACTURER. General Electric. MANUFACTURER PART NUMBER. HI NOTES: Solid State or Microprocessor based relays are generally equipped with a large variable of settings and curve options and some Electromechanical relays provide for adjustable calibrated settings. The / has three standard outputs. The main trip output is used to activate the breaker trip coil in the event of a fault. The auxiliary trip output can follow the trip relay, act as an 86 Lockout, or trip only on ground faults while the main trip output trips only on phase faults. The relay service output is used to provide the relay status. Date Code SEL Quick-Start Guide Quick-Start Guide I. Introduction This Quick-Start Guide explains how to install, configure, test, and operate the SEL Power Quality and Revenue Meter. For detailed information on these topics, please refer to the SEL Power Quality and Revenue Meter Instruction Manual located at www.doorway.ru

0コメント

  • 1000 / 1000